Remote control Sync parameter Arpeggio module is not working correctly
complete
Nikolozi
complete
Fixed in Mela 4.2 and AUM 1.4.5. If the issue is still happening, please leave a comment and I'll reopen it.
Nikolozi
in progress
The fix is available in build 102.
Nikolozi
under review
Nikolozi
AcoustiMan I'm a bit confused by the description. From the screenshot I see using KB-1 you are controlling LFO 3's Sync parameter, right? By the looks of it, the Sync parameter must be receiving some invalid/unexpected value because it's drawing full circles around the dial and the value is not even displayed. Not sure how that is possible.
And how is that related to Arpeggio? Is LFO 3 controlling the Arpeggio module?
AcoustiMan
Nikolozi: KB-01 is indeed controlling the sync parameter of LFO 3 which is controlling a parameter of the Arpeggio module.I found a workaround by inserting a Macro module which is connected to the Sync parameter of LFO 3. KB-01 is controlling the value slider of the macro.
Nikolozi
AcoustiMan: That's good that you found a workaround, but if there's a bug I would like to fix it. I still don't fully understand the issue.
> KB-01 is indeed controlling the sync parameter of LFO 3 which is controlling a parameter of the Arpeggio module.
- Which Arpeggio parameter was it controlling?
- Was the issue that LFO's Sync parameter was misbehaving? Like, how the dial is drawn incorrectly and not even displaying its current value?
AcoustiMan
Nikolozi: 1: On parameter of the Arpeggio module
2:Yes
Nikolozi
AcoustiMan: Cool, I've reproduced the issue. I'll investigate. Thanks for the feedback.
AcoustiMan
Nikolozi: 👍